GVU SERIES GAS DETECTION & VENTILATION CONTROL SYSTEMS
TYPICAL APPLICATIONS--
- Indoor Parking Garages
- Warehouses
- Post Office
- Police Stations
- Vehicle Maintenance Facilities
- Fire Stations
- Car Dealers
- Ice Arenas
The GVU Series of gas detection and ventilation control systems consist of five (5) main systems. Each of them can incorporate sensors for carbon monoxide (gasoline, LP, or natural gas powered engine emissions), carbon dioxide (diesel engine emissions), nitrogen dioxide (diesel engine emissions) and/or VOC (general air quality/diesel engine smoke). The GVU-1, GVU-3, GVU-6, GVU-12 and GVU-18 provide two (2) stages of relay contact outputs (warning and alarm). Warning contacts actuate when the sensor(s) sense a high level concentration lasting 30 seconds or more, and are generally used to turn on ventilation equipment. If the high level persists after an adjustable minimum fan run time, the alarm contacts will then close and signal (for example), an optional remote audible/visual alarm, direct digital controller, or turn on second stage ventilation. Each of the series comes with time clock functions for additional ventilation control. The GVU Series can act as a stand alone control system, or can be utilized with other types of building management systems.
Model GVU-1 [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Controller for one (1) remote sensor (CO, CO2, NO2, or VOC). Provides ventilation control with one (1) set each of warning and alarm contacts.
Model GVU-1A [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Same as GVU-1 except Model GVU-CO (CO) sensor is integral to the control unit.
Model GVU-1B [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Same as GVU-1 except Model GVU-CO2 (CO2) sensor is integral to the control unit.
Model GVU-1C [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Same as GVU-1 except Model GVU-VOC sensor is integral to the control unit.
Model GVU-1D [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Same as GVU-1 except Model GVU-NO2 (NO2) sensor is integral to the control unit.
Model GVU-3 [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Controller for up to three (3) remote sensors (CO, CO2, NO2, and/or VOC). Provides ventilation control with one (1) common set of warning and alarm contacts.
Model GVU-6 [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Controller for up to six (6) remote sensors (CO, CO2, NO2, and/or VOC). Provides ventilation control with warning and alarm contacts.
Model GVU-12 [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Controller for up to twelve (12) remote sensors (CO, CO2, NO2, and/or VOC). Provides ventilation control with warning and alarm contacts.
Model GVU-18 [Data Sheet] [Guide Specification] [Wiring Diagrams] [Options]
Controller for up to eighteen (18) remote sensors (CO, CO2, NO2, and/or VOC). Provides ventilation control with warning and alarm contacts.
Model GVU-CO (GVU-2R) [Data Sheet]
Carbon Monoxide (CO) Sensor
Model GVU-NO2 [Data Sheet]
Carbon Monoxide (CO) Sensor
Model GVU-CO2 [Data Sheet]
Carbon Dioxide (CO2) Sensor
Model GVU-VOC [Data Sheet]
Air Quality (VOC) Sensor
Accessories
Remote alarm panels, strobe lights, horns, calibration kits, etc.
|